Exhaust Fan Options for Your Storage Building
Maintaining good airflow is important for safe chemical storage. A chemical storage exhaust fan will help remove harmful fumes, vapors, and dust within your chemical storage building. Our engineers can calculate the right fan for adequate airflow and ventilation within your chemical storage building. Be sure to communicate clearly with your U.S. Chemical Storage Technical Sales Engineer about the types of chemicals and volume you’ll be storing, as well as if the building needs to be an occupancy building for workers or not. This information can help narrow down the correct chemical storage exhaust fan options for your storage building.
Exhaust fan
Explosion-Proof Exhaust Fans
An explosion proof exhaust fan system consists of an enclosed, explosion proof motor housed inside an exterior mounted enclosure for ventilation and fume removal. Explosion proof exhaust fans from U.S. Chemical Storage are completely enclosed for full explosion proof protection. They are designed to keep your chemical storage protected from harmful vapors and fumes. The interior exhaust vent is located within 12 inches of the floor for the extraction of heavier than air vapors. Exhaust fans are available in standard or high-capacity models. Your explosion proof exhaust fan system can be activated by a switch or can be wired for continuous operation
Additional Ventilation Options
Features & Benefits
- Weather-resistant steel construction
- Chemical & UV resistant coating
- Can be manufactured to meet EPA, NFPA 30 and NFPA 1
- Continuously welded, leak-tested sump
- Walk-in or rack style available
- 15-year structural warranty
Common Applications
- Hazardous Waste Storage
- Flammable and Combustible Storage
- Paint and solvent Storage
Downloadable Information & Fact Sheets
- Drawing: 2-Hour Bi-Direction Fire Rated Building (FL6115)
- Design Your Explosive Storage Magazine
- Warranty on Building & Accessories
- Buy or Build Chemical Storage Brochure
- Infographic: Choosing a Chemical Storage Building
- FireLoc 1-page Sheet
Compliance & Approvals
At U.S. Chemical Storage we strive to give you the best solution for your operations. This building and its accompanying accessories can be engineered to meet the following approvals and certifications based upon your unique set of needs.
Frequently Asked Questions
First consult the Safety Data Sheet (SDS) to determine the type of chemical you’re storing and any storage requirements listed. There are two main classifications of buildings to consider: fire-rated and non-fire-rated steel buildings.
There are three main questions you should answer before engineering or design can begin on your building: what is to be stored, how much of it is being stored, and where is the location it will be stored? You will also need to consult with your local “Authority Having Jurisdiction” (AHJ) or local code expert to determine your area’s specific storage building requirements.
Our team at U.S. Chemical Storage has a wealth of knowledge, experience, and resources to help analyze your storage needs, but the final approval is made by the local AHJ, so you will need to ultimately ask them about your requirements early in the planning process.
The definition of a “sump” is a pit or reservoir providing containment for spilled liquids. U.S. Chemical Storage offers leak-proof spill containment sumps in each standard model. All our sumps are tested for leaks for a 24-hour period prior to finishing. The sump is then covered by a steel or fiberglass floor grating and can even be equipped with a resistant plastic sump liner to protect against corrosive chemical accidental spills. The size of the sump is dictated by code based on the volume of liquid being stored within the building.
Building size is determined by the amount of hazardous material you are planning to store, the need for occupancy or inspection around these materials, and must take into consideration the most efficient way of moving these materials into and out of your chemical storage building.
Location of the building can be either inside another building or outside to fit your needs. Fire Separation, which is the amount of fire rating required between two occupancies, or the separation distance between those two occupancies, is determined by the type of chemical or hazard being stored, and distances between buildings, egress pathways, or environmental features. To determine the required fire separation, it is best to consult with your local code authority. Inside another building or within 10 feet of another building, you’ll be required to have a 4-hour fire rating. If your hazmat storage building is located at distances 30 feet or greater your building may not be required to have a fire rating at all.
Request a Quote
OTHER TYPES OF CLIMATE CONTROL ACCESSORIES
Cooling Options for Your Storage Building
Our air-conditioned chemical storage buildings allow for optimum temperature control while storing your hazardous materials safely.
Heating Options for Your Storage Building
U.S. Chemical Storage offers a wide variety of heating options for your chemical storage building.